Spectra Laser Level LL300 User Manual

LL300  
© 2004, Trimble Navigation Limited. All rights reserved  
PN Q102874  
 
TABLE OF CONTENTS  
GB  
FOR YOUR SAFETY  
5
Important Information  
COMPONENTS  
5
6
POWER SUPPLY  
6
Installing the Batteries  
Operating Time  
6
6
Charging the Batteries  
HOW TO USE THE LASER  
Laser Setup  
7
7
7
Self-leveling and Height (HI) Change Alert  
Manual-/Single Slope Mode  
OPERATING EXAMPLES  
Determining the Height of Instrument (HI)  
Marking Heights  
7
7
8
8
8
Vertical Application  
8
LEVELING ACCURACY  
Inuences on Leveling Accuracy  
Checking Calibration  
MAINTENANCE AND CARE  
SYSTEM CLEANING  
PROTECTING THE ENVIRONMENT  
WARRANTY  
SPECIFICATIONS  
9
9
9
10  
10  
10  
10  
11  
FOR YOUR SAFETY  
LASER RADIATION  
AVOID DIRECT EYE EXPOSURE  
CLASS 3R LASER PRODUCT  
• Do not remove warning labels from the unit.  
• The laser is subject to class 3R (< 5mW, 600 ... 680 nm).  
• Due to the small diameter beam, watch and secure the course of the beam in remote areas.  
Never look into the laser beam or direct it to the eyes of other people.  
• Always operate the unit in a way that prevents the beam from getting into people’s eyes.  
Important Information  
• Always place the laser in the middle of the working area.  
• Tripod/wall mount operation is recommended for distances over 20 m (65 ft).  
• Check the accuracy regularly.  
• Stable mounting is necessary for secure operations.  
• Keep the glass of the instrument clean.  
5
 
COMPONENTS  
Buttons  
1
2
Power Button  
Manual Button  
Control indicators  
3
4
5
Leveling Indicator  
Manual/HI-Warning Indicator  
Battery Indicator  
Elements of the unit  
6
7
8
9
Infrared Receiver (for remote control)  
Rotor Cage  
Sighting Guides  
Beam Aperture/Prism Cap  
10 Elastic Rubber Boot  
11 Handle  
12 Battery Door  
13 5/8x 11 Tripod Mounts  
14 Rubber Feet  
POWER SUPPLY  
Before using the unit for the rst time, install alkaline or rechargeable batteries. If Ni-Cads are used, rst  
recharge the batteries. See battery section.  
The Ni-Cad and Ni-MH batteries may contain small amounts of harmful substances.  
Be sure to charge the battery before using it for the rst time, and after not using it for an  
extended length of time. Charge only with specied chargers according to device manufacturer’s  
instructions.  
Do not open battery, dispose of in re or short circuit; it may ignite, explode, leak or get hot causing  
personal injury.  
Dispose in accordance with all applicable federal, state, and local regulations.  
Keep the battery away from children. If swallowed, do not induce vomiting. Seek medical attention  
immediately.  
Installing Batteries  
Remove the battery door by turning the center screw 90° counterclockwise. Insert batteries (or a rechargeable  
battery pack) into the housing so that the negative poles are on the bigger battery spiral springs.  
Install the battery door and tighten it by turning the center screw 90° clockwise.  
A mechanical switch prevents alkaline batteries from being charged. Only the original rechargeable  
battery pack allows charging within the unit. Any other rechargeable batteries have to be charged  
externally.  
Operating Time  
Rechargeable batteries permit an operating time of approx. 45 hours in rotation.  
Alkaline batteries (AIMn) permit an operating time of approx. 90 hours in rotation.  
The following factors reduce the operating time:  
• frequent self-leveling due to wind or vibration;  
• extreme temperatures;  
• old rechargeable batteries or rechargeable batteries with memory-effect;  
• using batteries of different capacities.  
Remove all batteries at the same time. Never use batteries with different capacities. Only use new  
(charged) batteries (rechargeable).  
Low voltage is indicated by the slow ashing battery indicator (5).  
6
 
Charging the batteries  
The charger requires approx. 10 hours to charge empty rechargeable batteries. For this charging, connect the  
plug of the charger to the recharge jack of the unit. New or long-time out-of-use rechargeable batteries reach  
their best performance after being charged and recharged ve times.  
The batteries should only be charged when the laser is between 50° F and 104° F (10° C to 40°  
C) Charging at a higher temperature may damage the batteries. Charging at a lower temperature  
may increase the charge time and decrease the charge capacity, resulting in loss of performance  
and shortened life expectancy.  
HOW TO USE THE LASER  
Laser Setup  
Position the unit horizontally (tripod mount and rubber feet downward!) on a stable platform, wall mount, or  
tripod at the desired elevation.  
Press the power button (1) to turn on the unit. The LEDs (3, 4 and 5) are turned on for 3 seconds. Self-leveling  
will start at once. The unit is leveled when the leveling indicator (3) is no longer ashing (once every second).  
The rotor will not spin until the unit is leveled. For the rst ve minutes after the laser self levels, the LED lights  
solid then ashes every four seconds to let you know the laser is still level.  
In order to switch the unit off, press the power button (1) again.  
If the laser is positioned beyond its self-leveling range of ±8%, the manual and leveling indicators ash  
simultaneously and a warning sound is emitted. Reposition the laser within its self-leveling range.  
Self-leveling, Height Change (HI) Alert  
Once turned on, the unit automatically levels itself in ranges of 8% (± 0.8 m / 10 m). In order to recognize  
the leveling process at the measuring area and in order not to mark faulty heights during this operation, the  
rotation stops.  
Once leveled, the unit constantly monitors its level condition. The height change (HI) alert is activated 5 minutes  
-1  
after self-leveling was performed and the laser is rotating at 600 min  
.
Level errors > 30 mm/10 m put the unit into alert mode because they are generally caused by a disturbance  
that could lead to inaccurate measurements. When entering into alert mode, the prism stops, the laser beam  
turns off, a warning sound is heard and the HI Warning LED (4) ashes 2 x per second. Turn the unit off and  
then on again. To ensure your former elevation, now you have to check or arrange the exact height.  
Manual Mode/Single Slope Mode  
When you press the ‘M’ button (2) on the laser, the remote control, or the receiver-remote control, the laser is  
set from automatic self-leveling mode to Manual mode. Manual mode is indicated by the ashing (once every  
second) red LED (4). In Manual mode, the Y-axis can be sloped by pressing the Up- and Down-Arrow-buttons  
on the remote control. Additionally, the X-axis can be sloped by pressing the Left- and Right-Arrow-buttons  
on the remote control.  
When you press the ‘M’ button again on the remote control, the laser is set into Single Slope mode. This is  
indicated by the ashing red (4) and green (3) LEDs (once every second). In Single Slope mode, the Y-axis  
can be sloped by pressing the Up- and Down-Arrow-buttons on the remote control, while the X-axis remains  
in automatic self leveling mode (e.g. when setting up ramps or drive ways). The Height change (HI) alert is  
still active.  
Pressing the manual button at the laser or remote control again, changes the laser back to automatic self-  
leveling mode as indicated by the ashing green LED (3).  
7
 
OPERATING EXAMPLES  
Determining the Height of Instrument (HI)  
The height of instrument (HI) is the elevation of the laser’s beam.  
The HI is determined by adding the grade-rod reading to a benchmark or known elevation.  
Set up the laser and place the grade rod on a job-site benchmark (BM) or known elevation.  
Slide the receiver up/down the grade rod until it shows an on-grade reading.  
Add the grade-rod reading to the benchmark to determine the height of instrument.  
Example:  
Benchmark  
Rod reading  
Height of instrument  
=
=
=
30.55 m (100.23 ft)  
+1.32 m (+4.34 ft)  
31.87 m (104.57 ft)  
Use this HI as a reference for all other elevations.  
Height of Instrument (HI)  
LL300  
Rod Reading  
1.32 m (4.34 ft)  
HI  
Benchmark  
30.55 m (100.23 ft)  
HI = Rod Reading + Benchmark  
HI = 1,32 m + 30,55 m = 31,87 m (4.34 ft + 100.23 ft = 104.57 ft)  
Marking Heights  
Set up the laser in horizontal mode (e.g., using a tripod or wall mount) so that the laser beam is at the  
desired height.  
When working without a tripod or wall mount, set up the laser on a stable surface and measure the height  
difference between laser beam and desired height by using a ruler and mark the measured height again.  
Vertical Application  
Level the tripod and allow the laser to level in automatic self-leveling mode.  
Push the manual mode button and change the laser’s position on the tripod for vertical alignment by using  
the vertical mounting thread.  
Rotate the laser until the vertical laser plane aligns with the receiver’s on-grade position.  
8
 
In order to avoid offset errors, the receiver should be used close to the elevation where the laser has been  
set up.  
If a remote control is available, the up and down arrow buttons can be used for ne adjustments.  
LEVELING ACCURACY  
Inuences on the leveling accuracy  
The overall accuracy of the unit can be inuenced by many factors:  
• factory accuracy;  
• temperature of the unit;  
• ambient inuences like rain, wind and temperature.  
The factor that inuences on the unit’s accuracy most is the ambient temperature. Vertical differences in  
temperature near the ground can divert the laser beam, similar to the heat waves seen on hot asphalt  
streets.  
This factor also applies to all optical measuring devices such as automatic levels and  
theodolites.  
Accuracy Check  
To ensure job-site accuracy, you need a distance of 20 m (65 feet) between two walls A and B, where you will  
execute 4 measuring operations on a tripod as follows (transit measurement).  
Set the unit horizontally on a tripod near wall A and switch it on with the plus X-axis pointing towards wall A.  
After the unit is level, mark the height of the laser beam using a receiver at wall A. Turn the entire unit 180°,  
let it self-level and mark the center of the laser beam at wall B.  
20m  
1
A
B
1.2  
1.1  
Now, place the unit near wall B with the plus X-axis pointing towards wall B. After the unit is level, mark the  
height of the laser beam at wall B. Turn the entire unit 180°, let it self-level and mark the center of the laser  
beam at wall A. The difference (h) of the marked points at wall A shows the deviation.  
9
 
2
A
2.2  
B
h
2.1=1.2  
1.1  
If the unit is within its working accuracy limits (± 20”) the maximum difference from true level at 20 m (65 ft.) +  
20 m (65 ft.) = 40 m (130 ft.) is 4 mm (3/16 inch).  
Repeat the above steps for “minus X” and for “plus-” and “minus Y”, so that a measurement for all four axes  
of the unit have been performed.  
The accuracy of the detector has to be regarded.  
PROTECTING THE UNIT  
Do not expose the unit to extreme temperatures or temperature changes (do not leave inside the car).  
The unit is very robust and can resist damage if dropped even from tripod height. Before continuing your work,  
always check the leveling accuracy. See Accuracy Check section.  
The laser is water proof and can be used indoors and outdoors.  
CLEANING AND MAINTENANCE  
Dirt and water on the glass parts of laser or prism will inuence beam quality and operating range considerably.  
Clean with cotton swabs.  
Remove dirt on the housing with a lint-free, warm, wet and smooth cloth. Do not use harsh cleansers or solvents.  
Allow the unit to air dry after cleaning it.  
PROTECTING THE ENVIRONMENT  
The unit, accessories and packaging should be recycled.  
This manual is made of non-chlorine recycling paper.  
All plastic parts are marked for recycling according to material type.  
Do not throw used batteries into the garbage, water or re. Remove them in compliance with  
environmental requirements.  
WARRANTY  
According to legal regulations, the warranty-period for this unit is 12 months for material and manufacturing  
defaults.  
We do not take any liability for damages caused by a non-accurate unit.  
Before starting to work, always carry out the Accuracy Check according to the corresponding  
chapter.  
This warranty is no longer valid if the unit is opened or the labels are removed.  
10  
 
SPECIFICATIONS  
1, 3  
Leveling Accuracy  
:
< ± 18 arc seconds, < ± 2.6 mm/30 m  
(< ± 3/32in./100 ft)  
Rotation Speed:  
Operating Range (Diameter  
Laser Type:  
600 rpm  
400 m (1315 feet)  
635 nm  
1,2  
:
Laser Class:  
Class 3R, <5mW  
Self-Leveling Range:  
Leveling Time:  
approx. ± 8% (approx. ± 4,8°)  
approx. 30 sec  
Leveling Indicators:  
Laser Beam Diameter :  
Power Source:  
Operating Temp.:  
Storage Temp.:  
LED ashes  
1
approx. 8 mm at the laser  
4 x D-cell NiCad or alkaline batteries (LR20)  
-20° C ... 50° C (-4° F...122° F)  
-20° C ... 70° C  
(-4° F...158° F)  
Tripod Mounts:  
Weight:  
5/8 x 11 horizontally and vertically  
2,7 kg  
Low voltage indication:  
Low voltage disconnection:  
ashing/shining of the battery indicator  
unit shuts off  
1) at 21° Celsius  
2) under optimal atmospheric circumstances  
3) along the axis  
DECLARATION OF CONFORMITY  
We  
Trimble Kaiserslautern GmbH  
declare under our sole responsibility that the product  
LL300  
to which this declaration relates is in conformity with the following standards  
EN 61000-4-2, 1995; EN 55011, 1998; EN 61000-4-3, 2002  
following the provisions of directive  
Electromagnetic compatibility 89/336/EEC.  
Kaiserslautern, den 17.03.2004  
Bernd Brieger  
The managing director  
11  
 

Sharp All in One Printer AL 1661CS User Manual
Sherwood Scuba Diving Equipment REGULATORS User Manual
Silvercrest Clock KH 2600 User Manual
Sonos Speaker System PLAY3US1 User Manual
Sony Car Stereo System MDS SP55 User Manual
Sony DVR HDR CX405 CX440 PJ410 PJ440 User Manual
Sony Laptop PCG 838 User Manual
Sony PDAs Smartphones PEG S320 User Manual
Stiga Lawn Mower 13 2535 12 User Manual
Sunbeam Kitchen Grill GR8210 User Manual